This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
private:writeups:plasmaimpedanceprobes [2020/07/01 19:13] admin |
private:writeups:plasmaimpedanceprobes [2020/07/02 14:17] (current) admin |
||
|---|---|---|---|
| Line 3: | Line 3: | ||
| === What it does === | === What it does === | ||
| - | 1. | + | Measures |
| - | Network analyzer performs | + | - Plasma frequency [Blackwell2005] |
| + | - Electron density (by measuring plasma | ||
| + | - Plasma potential | ||
| + | - Collision frequency | ||
| - | 2. Electron density [Blackwell2005] | + | === Methods === |
| - | Excite a two-stream instability [Blackwell2005]. | + | |
| - | === Advantages/ | + | PIPs can be operated in a number of methods |
| + | |||
| + | - Actively driven RF sweeps [Blackwell2005]. | ||
| + | - Plasma oscillation (excite a two stream instability) [Blackwell2005]. | ||
| + | |||
| + | |||
| + | === Advantages === | ||
| * [Blackwell2005] An improvement over Langmuir probes because contamination of the probe has a larger impact on its measurements than on the PIP. | * [Blackwell2005] An improvement over Langmuir probes because contamination of the probe has a larger impact on its measurements than on the PIP. | ||
| + | * Better resolution and accuracy than traditional Langmuir probes [citation] | ||
| + | |||
| + | === Disadvantages === | ||
| + | |||
| + | * More complicated. | ||
| + | * (Check this) Cannot be used in real-time because the network analyzer data can only be post-processed. | ||
| === Sources of error === | === Sources of error === | ||